Delta Industrial Power Supply SMPS 12V 12.5A 150W PMT-12V150W2BA
Including GST (No Hidden Charges)
Checkout securely with
Description:-
Delta Industrial Power Supply SMPS 12V 12.5A 150W PMT-12V150W2BA
Output Voltage: 12V
Output Power: 150W
Output Current: 12.5A
Input Voltage Range: 90-132Vac, 180-264Vac (Selectable by Switch)
Dimensions (L x W x H): 159 x 97 x 30 mm / 6.26” x 3.82” x 1.18”
Unit Weight: 0.354 kg (0.78 lb)
Certificates:-
Highlights and Features:-
- Household appliance approvals according to IEC/EN 60335-1, IEC/EN 61558-1 and IEC/EN 61558-2-16
- AC input voltage range selectable by switch (90-132Vac, 180-264Vac)
- No load power consumption < 0.5W
- Low profile design: 30mm height
- OVC III, Pollution Degree 3
- Wide operating temp -30°C ~ 70°C (Support -40°C cold start)
- Conforms to harmonic current IEC/EN 61000-3-2, Class A
- High MTBF > 700,000 hrs per Telcordia SR-332
- Compliance with SEMI-F47
Applications:
- Building Automation
- Machine Automation
- Process Automation
- Test & Measurement
- Factory Automation
- Household Appliance
Technical Specifications:-
Output:
Output Voltage Adjustment Range: |
10.8-13.2Vdc |
Output Power: |
150W |
Line Regulation: |
± 0.5% typ. @ 100-132Vac, 180-264Vac (Selectable by Switch) |
Load Regulation: |
± 0.5% typ. @ 100-132Vac, 180-264Vac (Selectable by Switch) |
PARD: |
< 150mVpp @ 0°C to 70°C 450mVpp typ. @ -30°C to 0°C |
Start-up Time: |
500ms typ. @ 115Vac & 230Vac |
Hold-up Time: |
30ms typ. @ 115Vac & 230Vac |
Dynamic Response (Overshoot & Undershoot O/P Voltage): |
Dynamic Response (Overshoot & Undershoot O/P Voltage): ± 10% @ 115 & 230Vac input, 10-100% load (Slew Rate: 2.5A/μS, 50% duty cycle @ 5Hz & 10KHz) |
Start-up with Capacitive Loads: |
8,000µF Ma |
Rise Time: |
30ms typ. @ 115Vac & 230Vac |
Input:
Nominal Input Voltage: |
100-120Vac, 200-240Vac (Selectable by Switch) |
Input Voltage Range: |
90-132Vac, 180-264Vac (Selectable by Switch) |
Nominal Input Frequency: |
50-60Hz |
Input Frequency Range: |
47-63Hz |
Input Current: |
3A typ. @ 115Vac, 1.7A typ. @ 230Vac |
Efficiency at 100% load: |
87.5% typ. Load @ 230Vac |
Max Inrush Current: |
60A typ. @ 230Vac (Cold Start) |
Leakage Current: |
< 0.5mA @ 240Vac/50Hz |
Mechanical:
Case Chassis / Cover: |
Aluminum / SGCC |
Indicator: |
Green LED (DC OK) |
Cooling System: |
Convection |
Noise Sound Pressure Level (SPL): |
< 25dBA |
Wire: |
AWG 18-12 |
Unit Weight: |
0.354 kg (0.78 lb) |
Dimensions: |
159 x 97 x 30 mm 6.26” x 3.82” x 1.18” |
Environment:
Vibration (Operating): |
IEC 60068-2-6, Sine Wave: 20Hz to 500Hz (5G); 10min per cycle, 60min for each axis (X, Y,Z)
|
Shock Test (Operating): |
IEC 60068-2-27, Half Sine Wave: 10G for a duration of 11ms, 3 shock for each 3 directions. |
Operating Temperature: |
-30°C to +70°C (-40°C Cold Start) |
Storage Temperature: |
-40°C to +85°C |
Power De-rating: |
> 50°C de-rate power by 2% / °C < -25°C de-rate power by 4% / °C @ 100Vac < 100Vac de-rate power by 1.33% / V (86.67% load @ 90Vac) |
Operating Humidity: |
20 to 90% RH (Non-Condensing) |
Shock Test (Non-Operating): |
IEC 60068-2-27, Half Sine Wave: 50G for a duration of 11ms, 3 shocks for each 3 directions |
Vibration (Non-Operating): |
IEC 60068-2-6, Random: 5Hz to 500Hz (2.09G); 20 min per axis for all X, Y, Z direction |
Operating Altitude: |
0 to 5,000 Meters (16,400 ft.) |
Pollution Degree: |
3 |
Over Voltage Category: |
II (Compliance to EN 62477-1 OVC III with 2000 meters altitude) |
Protections:
Overvoltage: |
13.2V-17.4V SELV Output, Latch Mode |
Overload / Overcurrent: |
110-175% of rated load current, Hiccup Mode, Non-Latching (Auto-Recovery) |
Over Temperature: |
Latch Mode |
Short Circuit: |
Hiccup Mode, Non-Latching (Auto-Recovery when the fault is removed) |
Protection Against Shock: |
Class I with Primary Earth connection |
Reliability:
MTBF: |
> 700,000 hrs as per Telcordia SR-332 I/P: 230Vac, O/P: 100% Load, Ta: 25°C) |
Expected Cap Life Time: |
10 years (230Vac, 50% load @ 40°C) |
Safety:
Electrical Safety: |
TUV Bauart: EN 62368-1, EN60335-1, EN 61558-1/-2-16 cULus: UL 62368-1 and CAN/CSA C22.2 No. 62368-1 CB scheme: IEC 62368-1, IEC 60950-1, IEC 60335-1, IEC 61558-1/-2-16 CCC: GB 4943.1 KC: K 60950-1 EAC: TP TC 004/2011 BSMI: CNS 14336-1 |
CE: |
In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU |
Galvanic Isolation: |
Input to Output: 4 KVac Input to Ground: 2.0 KVac Output to Ground: 1.25 KVac |
Safety Entry Low Voltage: |
SELV |
UKCA: |
In conformance with Electromagnetic Compatibility Regulations 2016 and Electrical Equipment (Safety) Regulations 2016 |
EMC:
Emission: |
(CE & RE) CISPR 32, EN/BS EN 55032, EN/BS EN 61000-6-4, KN32, AS/NZS CISPR32) Compliance to EN/BS EN 55014-1, FCC Title 47, EN/BS EN 61000-6-3 : Class B |
Immunity: |
EN/BS EN 55035, KN35, EN/BS EN 61000-6-2) Compliance to EN/BS EN 55014-2,EN/BS EN 61000-6-1 |
Harmonic Current Emissions: |
IEC/EN/BS EN 61000-3-2, Class A |
Product Includes:-