Delta Industrial Power Supply SMPS 12V 4.2AW PMT-12V50W2BA - Robodo
Delta Industrial Power Supply SMPS 12V 4.2AW PMT-12V50W2BA - Robodo

Delta Industrial Power Supply SMPS 12V 4.2AW PMT-12V50W2BA

Rs. 1,255.00 Rs. 1,150.00 SAVE 8%

Including GST (No Hidden Charges)

Add to Wishlist

Checkout securely with

SKU: PMT-12V50W2BA
Availability : In Stock Pre order Out of stock
Categories: Power Supply
Description

Delta Industrial Power Supply SMPS 12V 4.2AW PMT-12V50W2BA

DATASHEET

Specification:-

  • Output Voltage: 12V
  • Output Power: 50.4W
  • Output Current: 4.2A
  • Input Voltage Range: 90-264Vac
  • Dimensions (L x W x H): 99 x 82 x 29 mm / 3.90” x 3.23” x 1.14”
  • Unit Weight: 0.176 kg (0.39 lb)

Certificates:-

Highlights and Features:-

  • Household appliance approvals according to IEC/EN 60335-1, IEC/EN 61558-1 and IEC/EN 61558-2-16
  • Universal AC input voltage range
  • No load power consumption < 0.3W
  • Low profile design: 29mm height
  • OVC III, Pollution Degree 3
  • Wide operating temp -30°C ~ 70°C (Support -40°C cold start)
  • Conforms to harmonic current IEC/EN 61000-3-2, Class A
  • High MTBF > 700,000 hrs per Telcordia SR-332
  • Compliance with SEMI-F47

Applications:

  • Building Automation
  • Machine Automation
  • Process Automation
  • Test & Measurement
  • Factory Automation
  • Household Appliance

Technical Specifications:-

Output:

Output Current:

4.2A

Output Voltage:

12V

Output Voltage Adjustment Range:

10.8-13.2Vdc

Output Power:

50.4W

Line Regulation:

< 0.5% typ. (@ 115Vac & 230Vac input, 100% Load)

Load Regulation:

< 0.5% typ. (@ 115Vac & 230Vac input, 100% Load)

PARD:

< 120mVpp @ 0°C to 50°C

360mVpp typ. @ -30°C to 0°C

Start-up Time:

1,000ms typ. @ 115Vac, 500ms typ. @ 230Vac (100% load)

Hold-up Time:

15ms typ. @ 115Vac, 70ms typ. @ 230Vac

Dynamic Response (Overshoot & Undershoot O/P Voltage):

± 10% @ 115 & 230Vac input, 10-100% load (Slew Rate: 2.5A/μS, 50% duty cycle @ 5Hz & 10KHz)

Start-up with Capacitive Loads:

8,000µF Max

Rise Time:

30ms typ. @ 115Vac & 230Vac

 Input:

Nominal Input Voltage:

100-240Vac

Input Voltage Range:

90-264Vac

Nominal Input Frequency:

50-60Hz

Input Frequency Range:

47-63Hz

Input Current:

0.95A typ. @ 115Vac, 0.55A typ. @ 230Vac

Efficiency at 100% load:

85.0% typ. @ 230Vac

Max Inrush Current:

45A typ. @ 230Vac (Cold Start)

Leakage Current:

< 0.5mA @ 240Vac

Max Power Dissipation

0% load: 0.2W typ. @ 230Vac

 Mechanical:

Case Chassis / Cover:

Aluminum / SGCC

Indicator:

Green LED (DC OK)

Cooling System:

Convection

Unit Weight:

0.176 kg (0.39 lb)

Dimensions:

99 x 82 x 29 mm

3.90” x 3.23” x 1.14”

 Environment:

Vibration (Operating):

IEC 60068-2-6, Sine Wave: 20Hz to 500Hz (5G); 10min per cycle, 60min for each axis (X, Y,Z)

Shock Test (Operating):

IEC 60068-2-27, Half Sine Wave: 10G for a duration of 11ms, 3 shock for each 3 directions.

Operating Temperature:

-30°C to +70°C (-40°C Cold Start)

Storage Temperature:

-40°C to +85°C

Power De-rating:

> 50°C de-rate power by 2% / °C

< 100Vac de-rate power by 1.33% / V

(86.67% load @ 90Vac)

Operating Humidity:

20 to 90% RH (Non-Condensing)

Shock Test (Non-Operating):

IEC 60068-2-27, Half Sine Wave: 50G for a duration of 11ms, 3 shocks for each 3 directions

Vibration (Non-Operating):

IEC 60068-2-6, Random: 5Hz to 500Hz (2.09G); 20 min per axis for all X, Y, Z direction

Operating Altitude:

0 to 5,000 Meters (16,400 ft.)

Pollution Degree:

3

Over Voltage Category:

III (Compliance to EN 61558, EN 62477-1 with 2000 meters altitude)

 Protections:

Overvoltage:

13.2V-17.4V SELV Output, Latch Mode

Overload / Overcurrent:

110-175% of rated load current, Hiccup Mode, Non-Latching (Auto-Recovery)

Over Temperature:

Latch Mode

Short Circuit:

Hiccup Mode, Non-Latching (Auto-Recovery when the fault is removed)

Protection Against Shock:

Class I with PE*4 connection

 Reliability:

MTBF:

> 700,000 hrs as per Telcordia SR-332 I/P: 230Vac, O/P: 100% Load, Ta: 25°C)

Expected Cap Life Time:

10 years (230Vac, 50% load @ 40°C)

 Safety:

Electrical Safety:

TUV Bauart: EN 62368-1, EN 60335-1, EN 61558-1/-2-16

cULus: UL 62368-1, and CAN/CSA C22.2 No. 62368-1

CB scheme: IEC 62368-1, IEC 60950-1, IEC 60335-1, IEC 61558-1/-2-16

KC: K 60950-1

EAC: TP TC 004/2011

BSMI: CNS 14336-1

CCC: GB 4943.1

CE:

In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU

Galvanic Isolation:

Input to Output: 4.0 KVac

Input to Ground: 2.0 KVac

Output to Ground:1.25 KVac

Safety Entry Low Voltage:

SELV

UKCA:

In conformance with Electromagnetic Compatibility Regulations 2016 and Electrical Equipment (Safety) Regulations 2016

 EMC:

Emission:

(CE & RE)

CISPR 32, EN/BS EN 55032, KN 32, AS/NZS CISPR 32

Compliance to EN/BS EN 55014-1, FCC Title 47, EN/BS EN 61000-6-4, EN/BS EN 61000-6-3 : Class B

Immunity:

EN/BS EN 55035, KN 35

Compliance to EN/BS EN 55014-2, EN/BS EN 61000-6-2, EN/BS EN 61000-6-1

Harmonic Current Emissions:

IEC/EN/BS EN 61000-3-2, Class A

Voltage Fluctuation and Flicker:

IEC 61000-4-11

 

Product Includes:-

1x Delta Industrial Power Supply SMPS 12V 4.2AW PMT-12V50W2BA