Delta Industrial Power Supply SMPS 24V 4.5A 108W PMT-24V100W2BA
Including GST (No Hidden Charges)
Checkout securely with

The Delta Industrial Power Supply SMPS 24V 4.5A 108W PMT-24V100W2BA is a reliable and efficient switched-mode power supply (SMPS) designed to provide a stable 24V DC output with a 4.5A current, delivering 108W of total power output. Manufactured by Delta Electronics, this power supply is engineered for industrial, commercial, and automation applications where reliable and continuous power is essential. The unit features a wide input voltage range (90-264V AC), ensuring it can operate across various environments. It comes equipped with over-voltage, over-current, and short-circuit protection to ensure the safe operation of your equipment. The PMT-24V100W2BA is compact in size and boasts high efficiency, making it ideal for powering control systems, sensors, PLCs, and other essential equipment in a wide variety of industrial and commercial setups.
Delta Industrial Power Supply SMPS 24V 4.5A 108W PMT-24V100W2BA
Specification:-
- Output Voltage: 24V
- Output Power: 108W
- Output Current: 4.5A
- Input Voltage Range: 90-264Vac
- Dimensions (L x W x H): 129 x 97 x 30 mm / 5.08” x 3.82” x 1.18”
- Unit Weight: 0.285 kg (0.63 lb)
Certificates:-
Highlights and Features:-
- Household appliance approvals according to IEC/EN 60335-1, IEC/EN 61558-1 and IEC/EN 61558-2-16
- Universal AC input voltage range
- No load power consumption < 0.3W
- Low profile design: 30mm height
- OVC III, Pollution Degree 3
- Wide operating temp -30°C ~ 70°C (Support -40°C cold start)
- Conforms to harmonic current IEC/EN 61000-3-2, Class A
- High MTBF > 700,000 hrs per Telcordia SR-332
- Compliance with SEMI-F47
Applications:
- Building Automation
- Machine Automation
- Process Automation
- Test & Measurement
- Factory Automation
- Household Appliance
Technical Specifications:-
Output:
Output Current: |
4.5A |
Output Voltage: |
24V |
Output Voltage Adjustment Range: |
21.6-26.4Vdc |
Output Power: |
108W |
Line Regulation: |
± 0.5% (@ 115Vac & 230Vac input) |
Load Regulation: |
± 0.5% (@ 115Vac & 230Vac input) |
PARD: |
< 150mVpp @ 0°C to 70°C, 450mVpp typ. @ -30°C to 0°C |
Start-up Time: |
500ms typ. @ 115Vac & 230Vac (100% load) |
Hold-up Time: |
9ms typ. @ 115Vac, 42ms typ. @ 230Vac |
Dynamic Response (Overshoot & Undershoot O/P Voltage): |
± 10% @ 115 & 230Vac input, 10-100% load (Slew Rate: 2.5A/μS, 50% duty cycle @ 5Hz & 10KHz) |
Start-up with Capacitive Loads: |
8,000µF Max |
Rise Time: |
30ms typ. @ 115Vac & 230Vac |
Input:
Nominal Input Voltage: |
100-240Vac |
Input Voltage Range: |
90-264Vac |
Input Frequency Range: |
47-63Hz |
Input Current: |
1.9A typ. @ 115Vac, 1.2A typ. @ 230Vac |
Efficiency at 100% load: |
90.0% typ. @ 230Vac |
Max Inrush Current: |
55A typ. @ 230Vac (Cold Start) |
Leakage Current: |
< 0.5mA @ 240Vac |
Mechanical:
Case Chassis / Cover |
Aluminium / SGCC |
Indicator: |
Green LED (DC OK) |
Cooling System: |
Convection |
Unit Weight: |
0.285 kg (0.63 lb) |
Dimensions: |
129 x 97 x 30 mm 5.08” x 3.82” x 1.18” |
Environment:
Vibration (Operating): |
IEC 60068-2-6, Sine Wave: 20Hz to 500Hz (5G); 10min per cycle, 60min for each axis (X, Y,Z) |
Shock Test (Operating): |
IEC 60068-2-27, Half Sine Wave: 10G for a duration of 11ms, 3 shock for each 3 directions. |
Operating Temperature: |
-30°C to +70°C (-40°C Cold Start) |
Storage Temperature: |
-40°C to +85°C |
Power De-rating: |
> 50°C de-rate power by 2% / °C < 115Vac de-rate power by 0.6% / V (85% load @ 90Vac) |
Operating Humidity: |
20 to 90% RH (Non-Condensing) |
Shock Test (Non-Operating): |
IEC 60068-2-27, Half Sine Wave: 50G for a duration of 11ms, 3 shocks for each 3 directions |
Vibration (Non-Operating): |
IEC 60068-2-6, Random: 5Hz to 500Hz (2.09G); 20 min per axis for all X, Y, Z direction |
Operating Altitude: |
0 to 5,000 Meters (16,400 ft.) |
Pollution Degree: |
3 |
Over Voltage Category: |
II (Compliance to EN 62477-1 OVC III with 2000 meters altitude) |
Protections:
Overvoltage: |
26.4-33.6V SELV Output, Latch Mode |
Overload / Overcurrent: |
110-175% of rated load current, Hiccup Mode, Non-Latching (Auto-Recovery) |
Over Temperature: |
Latch Mode |
Short Circuit: |
Hiccup Mode, Non-Latching (Auto-Recovery when the fault is removed) |
Protection Against Shock: |
Class I with PE*4 connection |
Reliability:
MTBF: |
> 700,000 hrs as per Telcordia SR-332 I/P: 230Vac, O/P: 100% Load, Ta: 25°C) |
Expected Cap Life Time: |
10 years (230Vac, 50% load @ 40°C) |
Safety:
Electrical Safety: |
TUV Bauart: EN 62368-1, EN60335-1, EN 61558-1/-2-16 cULus: UL 62368-1 and CAN/CSA C22.2 No. 62368-1 CB scheme: IEC 62368-1, IEC 60950-1, IEC 60335-1, IEC 61558-1/-2-16 KC: K 60950-1 EAC: TP TC 004/2011 BSMI: CNS 14336-1 |
CE: |
In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU |
Galvanic Isolation: |
Input to Output:4.0 KVac Input to Ground: 2.0 KVac Output to Ground:1.25 KVac |
Safety Entry Low Voltage: |
SELV |
UKCA: |
In conformance with Electromagnetic Compatibility Regulations 2016 and Electrical Equipment (Safety) Regulations 2016 |
EMC:
Emission: |
(CE & RE) CISPR 32, EN/BS EN 55032, EN/BS EN 61000-6-4, KN32, AS/NZS CISPR32 Compliance to EN/BS EN 55014-1, FCC Title 47, EN/BS EN 61000-6-3 : Class B |
Immunity: |
EN/BS EN 55035, KN 35, EN/BS EN 61000-6-2 Compliance to EN/BS EN 55014-2,EN/BS EN 61000-6-1 |
Harmonic Current Emissions: |
IEC/EN/BS EN 61000-3-2, Class A |
Product Includes:-
1x Delta Industrial Power Supply SMPS 24V 4.5A 108W PMT-24V100W2BA