Delta Industrial Power Supply SMPS 24V 5A 120W DRL-24V120W1EN
Including GST (No Hidden Charges)
Checkout securely with

The Delta Industrial Power Supply SMPS 24V 5A 120W DRL-24V120W1EN is a highly efficient, compact, and reliable switched-mode power supply (SMPS) designed to provide stable and consistent 24V DC output with a 5A current, delivering a total power output of 120W. Built by Delta Electronics, a leading brand in industrial power solutions, this power supply is engineered for industrial, automation, and commercial applications where reliable and efficient power is needed. It features robust protection mechanisms such as over-voltage, over-current, and short-circuit protection, ensuring safe operation in various environments. The DRL-24V120W1EN model offers high efficiency and low standby power consumption, making it suitable for powering sensitive equipment, communication devices, and control systems.
Specification:-
- Output Voltage: 24V
- Output Power: 120W
- Output Current: 5A
- Input Voltage Range: 90-264Vac
- Dimensions (L x W x H): 123.6 x 30 x 116.8 mm / 4.87” x 1.18” x 4.60”
- Unit Weight: 0.45 kg (0.99 lb)
Certificates:-
Highlights and Features:-
- Universal AC input voltage range
- Built-in constant current circuit for reactive loads
- High power density
- Operate from -30°C to +70°C with -40°C Cold Start
- Reduced no-load power consumption
- Compliance with DOE VI Energy Standard
- Compliance to SEMI F47 @ 200Vac
Applications:
- Building Automation
- Machine Automation
- Process Automation
- Factory Automation
Technical Specifications:-
Output:
Output Current: |
5A |
Output Voltage: |
24V |
Output Voltage Range: |
21.6-26.4Vdc |
Output Voltage Adjustment Range: |
21.6-26.4Vdc |
Output Power: |
120W |
Line Regulation: |
± 0.5% @ 115Vac & 230Vac |
Load Regulation: |
± 0.5% |
PARD: |
< 150mp @ 0°C to +7Vp0°C < 450mVpp @ -30°C to 0°C |
Start-up Time: |
500ms typ. @ 115Vac & 230Vac |
Hold-up Time: |
10ms typ. @ 115Vac (100% load) 16ms typ. @ 230Vac (100% load) |
Dynamic Response (Overshoot & Undershoot O/P Voltage): |
± 10% @ 115Vac & 230Vac input, 10-100% load (Slew Rate: 2.5A/μS, 50% duty cycle @ 5Hz & 10KHz) |
Start-up with Capacitive Loads: |
q8,000µF Max |
Rise Time: |
30ms typ. @ 115Vac & 230Vac |
Input:
Nominal Input Voltage: |
100-240Vac |
Input Voltage Range: |
90-264Vac |
Nominal Input Frequency: |
50-60Hz |
Input Frequency Range: |
47-63Hz |
Input Current: |
2.1A typ. @ 115Vac, 1.3A typ. @ 230Vac |
Efficiency at 100% load: |
88.5% typ.@ 230Vac |
Max Inrush Current: |
35A typ. @ 230Vac |
Leakage Current: |
< 0.5mA @ 240Vac |
Mechanical:
Case Chassis / Cover: |
Aluminum / SGCC |
Indicator: |
Green LED (DC OK) |
Cooling System: |
Convection |
Input Terminal: |
3 Pins (Rated 300V/30A) |
Output Terminal: |
4 Pins (Rated 300V/20A) |
Noise Sound Pressure Level (SPL): |
< 25dBA |
Mounting Rail: |
Standard TS35 DIN Rail in accordance with EN 60715 |
Unit Weight: |
0.45 kg (0.99 lb) |
Dimensions: |
123.6 x 30 x 116.8 mm 4.87” x 1.18” x 4.60” |
Environment:
Vibration (Operating): |
IEC 60068-2-6, Sine Wave: 10Hz to 500Hz @ 19.6 m/s² (2G peak); 10 min per cycle, 60 min for X direction |
Shock Test (Operating): |
IEC 60068-2-27, Half Sine Wave: 10G for duration of 11ms; 1 time in X axis |
Operating Temperature: |
-30°C to +70°C (-40°C Cold Start) |
Storage Temperature: |
-40°C to +85°C |
Power De-rating: |
> 40°C de-rate power by 1.67 % / °C @115Vac > 50°C de-rate power by 2.5 % / °C @230Vac |
Operating Humidity: |
20 to 90% RH (Non-Condensing) |
Shock Test (Non-Operating): |
IEC 60068-2-27, Half Sine Wave: 50G for duration of 11ms; 3 times per direction, 9 times in total |
Vibration (Non-Operating): |
IEC 60068-2-6, Random: 5Hz to 500Hz (2.09G); 20 min per axis for all X, Y, Z direction |
Operating Altitude: |
0 to 5,000 Meters (16,400 ft.) |
Pollution Degree: |
2 |
Over Voltage Category: |
II (Compliance to EN 62477-1 OVC III with 2000 meters altitude) |
Protections:
Overvoltage: |
<33.6V, SELV Output, Latch Mode |
Overload / Overcurrent: |
105 - 150% of rated load current, Auto-recovery Continuous current limit Mode*5 (Vo>80%) |
Over Temperature: |
Latch Mode |
Short Circuit: |
Hiccup Mode, Non-Latching (Auto-Recovery when the fault is removed) |
Protection Against Shock: |
Class I with Primary Earth6 connection |
Internal Fuse: |
T4 A / 250 V |
Reliability:
MTBF: |
> 700,000 hrs. as per Telcordia SR-332 I/P: 115Vac & 230Vac, O/P: 100% load, Ta: 25°C |
Expected Cap Life Time: |
10 years (230Vac, 50% load @ 40°C) |
Safety:
Electrical Safety: |
CB scheme: IEC 62368-1, IEC 60950-1, IEC 61010-1 & -2-201 TUV Bauart: EN 62368-1, EN 61010-1 & -2-201 UL/cUL: UL 62368-1 CCC: GB4943.1 BSMI: CNS14336-1 EAC: TP TC 004/2011 KC: K 60950-1
|
CE: |
In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU |
UKCA: |
In conformance with Electrical Equipment (Safety) Regulations 2016 and Electromagnetic Compatibility Regulations 2016 |
EMC:
Emission: |
(CE & RE) CISPR 32, EN/BS EN 55032, EN/BS EN 61000-6-4, AS/NZS CISPR32, EN/BS EN 61204-3, KN 32 Compliance to FCC Title 47, EN/BS EN 61000-6-3: Class B |
Immunity: |
EN/BS EN 55035, KN 35, EN/BS EN 61000-6-2 Compliance to EN/BS EN 61000-6-1 |
Harmonic Current Emissions: |
IEC/EN/BS EN 61000-3-2, Class A |
Voltage Fluctuation and Flicker: |
IEC/EN/BS EN 61000-3-3 |
ESD Immunity: |
IEC 61000-4-2 |
Radiated Immunity: |
IEC 61000-4-3 |
EFT: |
IEC 61000-4-4 |
Surge: |
IEC 61000-4-5 |
Conducted Immunity: |
IEC 61000-4-6 |
Magnetic Field: |
IEC 61000-4-8 |
Voltage Dips: |
IEC 61000-4-11 |
Component Power Supply for General Use: |
EN/BS EN 61204-3 |
Product Includes:-
1x Delta Industrial Power Supply SMPS 24V 5A 120W DRL-24V120W1EN